Beijer-electronics AN-BEI-H2-038 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Beijer-electronics AN-BEI-H2-038. Beijer Electronics AN-BEI-H2-038 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 14
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
APPLICATIONNOTEANBEIH2038 Date:15/02/12
ANBEIH2038ModbusRTUControlandRegisterMapping
1
BFIApplicationsSupportLibrary
ApplicationNote ANBEIP2038
Title ModbusRTUControlandRegisterMapping
RelatedProducts BeijerFrequencyInverterH2
Level
3
1Fundamental‐Nopreviousexperiencenecessary
2BasicSomeBasicdrivesknowledgerecommended
3AdvancedSomeBasicdrivesknowledgerequired
4ExpertGoodexperienceintopicofsubjectmatterrecommended
Overview:
ThisdocumentprovidesinformationontheModbusRTUmemorymappingthatisimplementedintheBeijerFrequencyInverter
H2drives,detailingwhichaddressesareusedtoreadandwritedatato/fromtheBeijerFrequencyInverterH2inaModbusRTU
network.AlldataregisterswithinthedriveareHolding
Registers,andcanbeaccessedbymeansoftheModbuscommands03
ReadMultipleHoldingRegistersand06WriteSingleRegisteronly.
TheModbusRequestPDU specifies the starting registeraddressandthe numberofregisters.In this case, with some Modbus
Master Systems, it may be necessary to subtract
1 from the register number (e.g. some systems treat holding register 1 as
address0).
TheManufactureradoptsapolicyofcontinuousimprovementandwhilsteveryefforthasbeenmadetoprovideaccurateandup
todateinformation,theinformationcontainedinthisdocumentshouldbeusedforguidancepurposes
onlyanddoesnotform
thepartofanycontract.
MODBUSRTUProtocolSpecification:
ThefollowingtablehighlightsthespecificationfortheModbusRTUimplementation.
Protocol ModbusRTU
Errorcheck CRC
Baudrate ParameterSelectableasfollows:
9600bps,19200bps,38400bps,57600bps,115200bps(default)
Dataformat ParameterSelectableasfollows:
1startbit,8databits,1stopbits,noparity.(default)
1startbit,8databits,2stopbits,noparity.
1startbit,8databits,1stopbits,evenparity.
1startbit,8databits,1stopbits,odd
parity.
Physicalsignal RS485(2wire)
Przeglądanie stron 0
1 2 3 4 5 6 ... 13 14

Podsumowanie treści

Strona 1 - Overview:

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping1BFIApplicationsSupportLibraryApplicati

Strona 2 - ModbusTelegramStructure:

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping10Group6:AdvancedParameterset(Level3)P

Strona 3

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping11Group8:ApplicationSpecificParameters‐

Strona 4

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping12DriveErrorCodeInformation:In the event

Strona 5

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping13ModbusExceptionResponseTelegrams:Unders

Strona 6 - DriveParameters:

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping14Appendix:RevisionHistoryVersion Comments

Strona 7

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping2ModbusTelegramStructure:ThefollowingModb

Strona 8

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping3MemoryMap:Table1:Controlandstatusregis

Strona 9

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping461 Userregister11 03,06 Read/Write62 Use

Strona 10

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping5Register8:OutputCurrentThisregisterdisp

Strona 11

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping6DriveParameters:All User Adjustable para

Strona 12

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping7Group2:Extendedparameterset(Level2)Pa

Strona 13 - Dataflowexample:

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping8Parameter RegisterNumberDescription Range

Strona 14

APPLICATIONNOTEAN‐BEI‐H2‐038 Date:15/02/12AN‐BEI‐H2‐038ModbusRTUControlandRegisterMapping9Group3:UserPIDcontrol(Level2)P

Komentarze do niniejszej Instrukcji

Brak uwag