Command Reference
106 Beijer Electronics, MAEN975
6.60 LAU_STATUS_IPADR (0x0301)
Current IP Address
Returns the current IP address of the monitor. If a DHCP server is used, this is the
IP address assigned by the DHCP server. If no DHCP server is used, this is the con-
figured static IP address.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
12
Example
Read the current IP address of monitor at address 0.7 (group 0, address 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitors current IP-address is 192.168.4.240:
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x03 0x01 ICHKD
0 1 2 3 4 5 6 7...10 11
0x06 ADR
0x4C 0x41 0x55 0x04 ICHKH Ret ICHKD
Ret
Value: 0...255 each byte
Type: Byte array
Length: 4
Description: IP address, where the first byte is the highest address field
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x03 0x01 0xFB
0 1 2 3 4 5 6 7...10 11
0x06 0x07
0x4C 0x41 0x55 0x04 0x0C 0xC0 0xA8 0x04 0xF0 0xA3